sisHYD User Guide

Update Pipe Lengths

The assistant serves to examine and correct the pipe lengths in the project. It compares the entered pipe lengths and the length resulting from the pipe process. The evaluation of the comparison is offered as a HTML log.

Configure Pipe Length Wizard

  • Only list pipes above threshold value – If this field is marked, only pipes whose absolute difference is greater than the displayed minimum difference is logged when the examination occurs. The standard threshold value is 0.5 m.
  • Use Threshold value – Mark this field to set the threshold value yourself.
  • Minimum Difference – Threshold value for the absolute length difference above which a pipe is logged.

Check pipe lengths

  • Display log of the length comparison – Opens the HTML log file and lists all pipes which are above the minimum difference in the length comparison. Apart from the absolute difference, the table shows the current and calculated pipe lengths.
  • Adopt calculated lengths – Before sisHYD changes the lengths in the data volume and transfers the calculated lengths as new pipe lengths, this field must be marked.

Update pipe lengths

The assistant displays the progress of the update of pipe lengths. Click Finish to leave the assistant.